Mycoplasma testing by PCR

Screen culture supernatant for mycoplasma with a 16S rRNA PCR, with positive and negative controls.

Total time3 h
Hands-on30 min
LevelBasic
Steps5
0 of 5 steps done

Before you start

  • Culture cells for at least 3 days without antibiotics before sampling.

Reagents and materials

Totals are for 6 cell lines (+10% extra). Per-cell line amounts are in the middle column.

ReagentPer cell lineTotal
Culture supernatant (cells near confluence, ≥ 3 days without antibiotics)100 µL100 µL
PCR master mix with mycoplasma primers (kit)23 µL23 µL
Heat-treated supernatant (template)2 µL2 µL

Equipment

  • Heat block (95 °C)
  • Thermocycler
  • Agarose gel set-up

Procedure

Tick steps as you go (saved in this browser). Steps with a clock have a built-in timer.

  1. Collect supernatant

    Take 100 µL supernatant from a dense culture.

  2. Heat

    Heat at 95 °C for 5–10 min, then spin down debris.

  3. Set up PCR

    Add 2 µL to the PCR mix; include the kit positive control, a negative (water) control and, if supplied, an internal control.

  4. Run PCR

    Run the kit’s cycling program.

  5. Analyse

    Run on an agarose gel and compare with controls; a band of the expected size indicates mycoplasma.

Critical points

  • Test new lines on arrival and all lines regularly (for example monthly).
  • Quarantine untested lines in a separate incubator.

Troubleshooting

ProblemWhat to check or change
Positive resultDiscard the culture (preferred) or treat with an anti-mycoplasma reagent and re-test; check other lines in the same incubator.
Inhibited PCRDilute the template 1:10.

Safety

Standard practice for your cell line’s biosafety level.

Further reading

  • Uphoff CC, Drexler HG. Detection of mycoplasma contamination in cell cultures. Current Protocols in Molecular Biology (2014).

This is a general starting-point protocol written for SolvesEverything. Follow your institution’s approved protocols, safety rules and manufacturers’ instructions, and optimise for your system. Spotted an error? Tell us.