Antibiotic susceptibility by disk diffusion (Kirby–Bauer)

Test bacterial susceptibility by measuring inhibition zones around antibiotic disks on Mueller–Hinton agar.

Total time30 min + 16–18 h
Hands-on30 min
LevelIntermediate
Steps5
0 of 5 steps done

Before you start

  • Use pure overnight colonies.
  • Use current CLSI or EUCAST breakpoint tables and quality-control strains.

Reagents and materials

Totals are for 4 isolates (+10% extra). Per-isolate amounts are in the middle column.

ReagentPer isolateTotal
Mueller–Hinton agar plate (4 mm depth)1 each1 each
Saline for 0.5 McFarland suspension2 mL2 mL
Antibiotic disks6 each6 each
Sterile swab1 each1 each

Equipment

  • 0.5 McFarland standard or densitometer
  • Disk dispenser or forceps
  • 35 °C incubator
  • Ruler or calipers

Procedure

Tick steps as you go (saved in this browser). Steps with a clock have a built-in timer.

  1. Prepare inoculum

    Suspend colonies in saline to match a 0.5 McFarland standard (~1.5 × 10⁸ CFU/mL); use within 15 min.

  2. Inoculate

    Dip a swab, remove excess and swab the whole plate in three directions, rotating 60° each time.

  3. Apply disks

    Within 15 min, place disks firmly at least 24 mm apart.

  4. Incubate

    Incubate inverted at 35 ± 2 °C for 16–18 h.

  5. Measure

    Measure zone diameters in mm and interpret as susceptible, intermediate/susceptible-increased-exposure, or resistant using current breakpoints.

Critical points

  • Inoculum density and agar depth strongly affect zone size.
  • Run QC strains with known zone ranges each time.

Troubleshooting

ProblemWhat to check or change
Zones out of QC rangeCheck inoculum, disk storage, agar depth and incubation.

Safety

Clinical isolates may require BSL-2 practices.

Further reading

  • CLSI M02 Performance Standards for Antimicrobial Disk Susceptibility Tests; EUCAST disk diffusion method.

This is a general starting-point protocol written for SolvesEverything. Follow your institution’s approved protocols, safety rules and manufacturers’ instructions, and optimise for your system. Spotted an error? Tell us.